fault phenomenon | Possible causes | elimination methods |
Loud vibration | 1)Suction line or pump suction end leakage or blockage; 2)The suction height exceeds the suction vacuum height of the pump; 3)bearing failure | 1)Eliminate air leaks or clogs; 2)Reduce suction height to reduce pipe resistance 3)bearing replacement |
Large pressure fluctuation | 1)Suction line or pump suction end leakage or blockage; 2)The suction height exceeds the suction vacuum height of the pump; | 1)Eliminate air leaks or clogs; 2)Reduce suction height to reduce pipe resistance |
| 1)Suction line or pump suction end leakage or blockage; 2)The suction height exceeds the suction vacuum height of the pump; 3)The speed is too low; 4)Screw sleeve, pump bushing wear; 5)Shaft seal leaks. | 1)Eliminate air leaks or clogs; 2)Reduce suction height to reduce pipe resistance 3)Increase the speed; 4)Replace worn parts; 5)Repair and replace shaft seal components. |
Can't pump up the volume | 1)Suction line or pump suction end leakage or blockage; 2)The suction height exceeds the suction vacuum height of the pump; 3)Screw sleeve, pump bushing wear; 4)The shaft turned in reverse. | 1)Eliminate air leaks or clogs; 2)Reduce suction height to reduce pipe resistance 3)Replace worn parts; 4)Adjust motor steering. |
power augmentation | 1)The viscosity of the conveying medium increases; 2)Severe wear inside the pump; 3)Pumps and motors are different; 4)The outlet line is blocked. | 1)Temperature rise reduces viscosity; 2)Repair and replace related wear parts; 3)Correction concentricity; 4)Remove the blockage. |
Pump body heating | 1)Screw sleeve wear; 2)Severe wear inside the pump; 3)Pumps and motors are different; 4)The outlet line is blocked. | 1)Replace worn parts; 2)Correction concentricity; 3)Remove the blockage. |
Mechanical seal heating | 1)The mechanical seal flushing pipe is blocked; 2)The compression of mechanical seal is too large. | 1)Dredge the cleaning pipe; 2)Adjust the compression of the seal. |
Mechanical seal leakage | 1)Mechanical seal compression is too small; 2)Mechanical seal wear, seal element damage. | 1)Adjust the compression of the seal; 2)Change seal |
Contact: Kevin.Bai
Phone: +86-15342756326
E-mail: whlnshb@163.com
Add: 100 meters east of gas station at the intersection of Qianzishan Avenue and Jiukang Avenue, Caidian District, Wuhan City, Hubei Province